Regulatory posture
This document records the regulatory line the design respects. It is the explicit answer to the question “is this thing a medical device?” The answer is no. The rest of this document is the work it took to be able to say that with a straight face.
Scope of this document
Section titled “Scope of this document”This is a public reference implementation. It is not a product. It is not marketed, distributed, or made available to clinicians or patients for clinical use. The audience is engineers and AI peers reading the project as a reference artefact. Even with that audience, the design honours the regulatory boundaries that would apply if the same code were ever taken to production. The intent is twofold: keep the reference free of any claim that would re-classify it as a device, and demonstrate an understanding of the boundary well enough to build inside it.
The boundary is anchored against four reference documents, summarised below.
Reference documents
Section titled “Reference documents”FDA - Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations (Draft, January 2025)
Section titled “FDA - Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations (Draft, January 2025)”Published 7 January 2025. The draft guidance describes the marketing submission contents and lifecycle-management practices the FDA expects for AI-enabled device software functions, including predetermined change control plans for models that learn over time. It is the operational sequel to the 2024 final guidance on Predetermined Change Control Plans. The document does not by itself decide whether a piece of software is a device - that question is decided under section 520(o) of the FD&C Act and the related CDS / general-wellness guidance below - but it sets the expectations for any product that crosses into device territory.
This reference implementation is not a device, so the marketing-submission contents are not authored. The lifecycle expectations are nonetheless tracked as design discipline: model + dataset cards, versioning of model
- KB + prompts together, an eval harness that gates changes, observability that records production-relevant traces.
FDA - Revised Clinical Decision Support Software guidance and revised General Wellness: Policy for Low Risk Devices (January 2026)
Section titled “FDA - Revised Clinical Decision Support Software guidance and revised General Wellness: Policy for Low Risk Devices (January 2026)”Published 6 January 2026. The revised CDS guidance clarifies the four statutory criteria under section 520(o)(1)(E) of the FD&C Act that exempt CDS software from being regulated as a device when the software is intended for a health-care professional, displays the basis for its recommendation transparently, and gives the HCP an independent means to review that basis. The revised general-wellness guidance reaffirms that software intended to maintain or encourage a healthy lifestyle, and unrelated to the diagnosis, cure, mitigation, prevention, or treatment of a disease or condition, is not a device. The 2026 revisions broadened the wellness category to include non-invasive sensing of physiological parameters when output solely for wellness purposes, and narrowed the CDS scope around single-recommended-treatment-option tools and risk-probability outputs.
The agent in this reference implementation is patient-facing, not clinician-facing. That places it firmly outside the CDS exemption regardless of the 2026 revisions, because the CDS exemption is conditioned on HCP-facing-with-independent-review. The agent therefore must avoid any function that would qualify it as a device under 520(o) on the patient-facing path: no diagnosis, no treatment recommendation, no prescription change, no labs/imaging interpretation. The agent stays on the general-wellness side of the line - adherence support, lifestyle encouragement, MI-style reflection - and refuses anything that would cross over. Refusal templates and the scope classifier enforce this; the eval harness measures compliance.
WHO - Ethics and governance of artificial intelligence for health: Guidance on large multi-modal models (January 2024)
Section titled “WHO - Ethics and governance of artificial intelligence for health: Guidance on large multi-modal models (January 2024)”Published 18 January 2024. The WHO guidance is a forty-recommendation framework addressed to governments, technology providers, and health systems. The core themes the design honours: transparency about model and training-data provenance, accountability for outputs, avoidance of bias, protection of patient autonomy, and human oversight on high-stakes decisions. Specific WHO recommendations operationalised here: model and dataset cards (transparency), citation-on-assertion (accountability), locale parity in evals (bias avoidance), refusal and escalation defaults (autonomy protection and human oversight).
URL: https://www.who.int/publications/i/item/9789240084759
MHRA - AI Airlock pilot and Good Machine Learning Practice
Section titled “MHRA - AI Airlock pilot and Good Machine Learning Practice”The MHRA’s AI Airlock pilot ran in the 2024-2025 financial year as a regulatory sandbox for software-as-a-medical-device with generative AI or machine-learning components. Five sandbox candidates completed the full pilot; a sandbox programme report was published in October 2025. GMLP - Good Machine Learning Practice - is a ten-principle joint publication from the MHRA, FDA, and Health Canada that frames how ML-enabled medical devices should be developed, deployed, and monitored. The 2025 MHRA roadmap commits to a GMLP-aligned guidance publication. The design tracks the ten GMLP principles as design discipline: multi-disciplinary expertise, sound engineering practice, clinically relevant data, training-test independence, focus on the performance of the human-AI team, testing on representative data, transparency to users, deployed-model monitoring, periodic re-training, and informed user community.
URLs:
- AI Airlock programme: https://www.gov.uk/government/news/ai-airlock-cersis-and-a-new-global-ai-network-for-health-regulators
- AI Airlock pilot report: https://assets.publishing.service.gov.uk/media/68ee1fb88427701993d5e02c/AI_Airlock_Sandbox_Programme_Report_Final.pdf
- GMLP guiding principles (FDA mirror): https://www.fda.gov/medical-devices/software-medical-device-samd/good-machine-learning-practice-medical-device-development-guiding-principles
EU AI Act - Regulation (EU) 2024/1689 (in force August 2024, high-risk obligations applicable August 2026)
Section titled “EU AI Act - Regulation (EU) 2024/1689 (in force August 2024, high-risk obligations applicable August 2026)”Published 13 June 2024, entered into force 1 August 2024, with the prohibited-practices articles applicable from 2 February 2025 and the bulk of the high-risk-system obligations applicable from 2 August 2026. The Act classifies AI systems by risk tier. Annex III enumerates the high-risk use cases that trigger the conformity-assessment, risk-management, data-governance, technical-documentation, post-market-monitoring, and human-oversight obligations of Chapter III Section 2. Three Annex III categories are adjacent to the design space of this reference implementation and worth naming explicitly:
- Annex III point 5(a) - AI systems intended to be used by public authorities to evaluate the eligibility of natural persons for essential public services and benefits.
- Annex III point 5(b) - AI systems intended to be used to evaluate the creditworthiness of natural persons or establish their credit score.
- Annex III point 5(d) - AI systems intended to be used to dispatch, or to establish priority in the dispatching of, emergency-service first-responders, including by triage.
A patient-facing medication-adherence wellness coach is not, in itself, an Annex III high-risk system. The agent does not triage emergency calls, does not allocate public benefits, does not score creditworthiness. The “Red-flag escalation” branch of the agent recognises acute clinical red-flag patterns and surfaces local emergency-services guidance without acting as a triage tool itself. The escalation logic is deliberately deterministic and rule-based so that the human operator, not the model, holds the routing decision.
Where the EU AI Act is most relevant to this reference implementation is not in the risk-tier classification of the agent itself but in the model-governance posture the harness encodes. Article 9 (risk-management system), Article 10 (data and data governance), Article 11 + Annex IV (technical documentation), Article 12 (record-keeping), Article 13 (transparency), Article 14 (human oversight), Article 15 (accuracy / robustness / cybersecurity), and Article 17 (quality-management system) are the procedural surface a high-risk Annex III deployer has to satisfy. The harness shipped here sits in that procedural layer: eval contracts with explicit acceptance thresholds, data cards naming each source, PR-blocking cost and citation gates, OpenInference-traced spans for every turn, refusal templates with human-readable rationale, and the orchestrator’s deterministic escalation router. Adopting these patterns into an Annex III system inside a regulated organisation accelerates the Article 9 + 10 + 12 + 14 evidence pack; it does not satisfy those articles on its own.
For a downstream operator whose own AI system is Annex III high-risk (for example, a public-sector eligibility assistant or a credit-scoring chatbot), the harness pattern transfers in three concrete ways: (i) the eval contract gives the risk-management system in Article 9 a testable artefact; (ii) the citation-required + refusal-on-no-match contract narrows the surface where Article 15 accuracy / robustness can fail silently; (iii) the per-span OpenTelemetry trace gives the record-keeping in Article 12 a wire-format-agnostic, vendor-portable backbone.
URLs:
- Regulation (EU) 2024/1689 official text: https://eur-lex.europa.eu/eli/reg/2024/1689/oj
- Annex III consolidated list: https://artificialintelligenceact.eu/annex/3/
- European AI Office: https://digital-strategy.ec.europa.eu/en/policies/ai-office
The wellness / CDS boundary the design respects
Section titled “The wellness / CDS boundary the design respects”The design draws a hard line: the agent is a wellness-support tool that addresses medication-adherence behaviour, not a clinical-decision tool. Concretely:
- The user is a patient, not a clinician. The CDS exemption is HCP- facing; the wellness pathway is patient-facing. The agent stays patient-facing for that reason.
- The agent addresses the behavioural side of adherence (motivation, routine, reminders, MI-style reflection on barriers) and never the clinical side (whether the regimen is correct, whether to change it, what the labs mean).
- The agent never substitutes for a clinician interaction. It always carries the disclaimer that clinical questions go to the user’s health-care provider, and it escalates explicit acute red flags by surfacing emergency-services guidance and ending the in-app interaction. A small number of patterns are handled by the LLM and system-prompt layer rather than the deterministic router; see ADR-0005.
What the agent does NOT do
Section titled “What the agent does NOT do”This list is the canonical statement of out-of-scope behaviour. It is enforced by the scope classifier, by the refusal templates, and by the eval harness.
- No diagnosis. The agent never names, infers, or rules in/out a medical condition. If the user describes symptoms, the agent acknowledges, encourages contact with a clinician, and (if the symptoms match an escalation rule) surfaces emergency-services guidance.
- No dosing advice. The agent never tells the user to take more, take less, double up after a miss, split a dose, skip a dose, or change a dosing schedule. Dosing questions are refused and redirected to the prescribing clinician or pharmacist.
- No prescription change. The agent never advises starting, stopping, switching, substituting, or pausing a medication. The refusal template names the prescribing clinician as the correct contact.
- No interpretation of labs, imaging, or device readings. The agent never reads numerical values back as clinical interpretation (“your A1c of 7.4 means …”). It acknowledges that the user has the data, encourages clinician review, and disengages from interpretation.
- No clinician-facing interaction. The agent’s surface is the patient. It does not produce HCP-facing summaries, structured clinical notes, or any artefact targeted at a clinician’s workflow. (HCP-facing tools would be subject to the CDS exemption test and would change the regulatory posture entirely.)
- No emergency-services replacement. On any escalation trigger, the agent surfaces the relevant emergency number and disengages. It is not a triage tool.
- No claim of clinical validation. No language in any agent response or any project artefact will claim the system has been clinically validated, trialled, or endorsed by a regulatory body.
Disclaimers required in every demo response
Section titled “Disclaimers required in every demo response”Every response the agent emits in the live demo carries two artefacts:
- A persistent banner in the Spaces UI: “Reference implementation. 100% synthetic data. Not a medical device. For demonstration only. Speak to your clinician for medical advice. In an emergency, call your local emergency services.”
- An inline footer on every assistant turn, surfaced through the response template: “This is a demonstration. Not medical advice.”
The eval harness checks for the inline footer on every turn and treats its absence as a safety regression.
Change control for the regulatory posture
Section titled “Change control for the regulatory posture”A change to this document - broadening the scope of permitted agent behaviour, narrowing the refusal list, removing a disclaimer, changing the escalation criteria - requires an Architecture Decision Record in the guardrails area. The ADR is the place to record the rationale, the new boundary, and the eval-harness changes that enforce it. The release notes for that change record it in the security section, because regulatory posture is a security-relevant property of the system.
Human review posture
Section titled “Human review posture”Human-in-the-loop review is an optional capability of this agent that can pause a response for human approval before delivery. It is off by default in this demonstration. Enabling it for a production deployment requires additional infrastructure and is documented as a prerequisite in the private operator command reference.
The acute red-flag escalation path routes directly through the deterministic guardrail, not through the human-review step. Those turns are never paused; the guardrail short-circuits the review node on every acute turn.
Production path: A production deployment that enables human review must provision a durable checkpointer backend and configure the service accordingly. Consult the deployment documentation for the prerequisite steps.